Unique, compact unit that combines filtration and pressure regulation in one piece for protection of downstream components in a low-volume irrigation system.
Reduces the number of components in a control zone, making it smaller and easier to install. More control zones can fit in one valve box!
Combination unit reduces the number of connections, making installation easier and faster.
Increased reliability - fewer parts and fewer threaded connections mean less chance of a leak both at installation and over the life of the system.
Static RBY filter regulates pressure to a nominal 30 or 40 psi (2.0 or 2.8 bar).
|
|
*Available with BSP threads. |
|
In order to supply 40 psi (2.8 bars) outlet pressure, additional pressure is needed at the inlet since there is some pressure loss from water flowing through the kit. The amount of pressure loss depends on the flowrate.
The charts below list the minimum inlet pressure required to supply 40 psi (2.8 bars) of outlet pressure.
| Pressure Loss Characteristics | ||
| Flow (gpm) | PRF-075-RBY (psi) | PRF-100-RBY (psi) |
| 0.2 | 3.0 | N/A |
| 1.0 | 4.0 | N/A |
| 3.0 | 6.1 | 0.8 |
| 5.0 | 10.0 | 2.0 |
| 8.0 | N/A | 3.8 |
| 10.0 | N/A | 5.2 |
| 15.0 | N/A | 12.0 |
Metric
| Pressure Loss Characteristics | ||
| Flow (l/m) | PRF-075-RBY (bar) | PRF-100-RBY (bar) |
| 0.8 | 0.21 | N/A |
| 3.8 | 0.28 | N/A |
| 11.4 | 0.42 | 0.06 |
| 18.9 | 0.69 | 0.14 |
| 30.3 | N/A | 0.26 |
| 37.9 | N/A | 0.36 |
| 56.8 | N/A | 0.83 |