PRS-D module is recommended for use only
at flow rates in the shaded area. Loss values are with
flow control fully open.
English, Pressure Loss
(psi)
Flow (GPM)
100-GB (1")
125-GB (1 1/4")
150-GB (1 1/2")
200-GB (2")
5
0.4
-
-
-
10
0.8
-
-
-
15
1.2
-
-
-
20
2.1
1.4
2.3
0.6
30
5
2.3
2.9
0.7
40
8.2
4.1
2
0.9
50
13
6.8
3.3
1.1
60
-
9.8
4.6
1.7
80
-
16.5
7.5
2.6
100
-
-
11.8
3.9
120
-
-
16.6
5.9
140
-
-
-
7.8
160
-
-
-
10
180
-
-
-
12.4
200
-
-
-
15.1
Metric, Pressure Loss
(bar)
Flow (m³/h)
Flow (l/m)
100-GB (1")
125-GB (1 1/4")
150-GB (1 1/2")
200-GB (2")
1
19
0,03
-
-
-
3
50
0,07
-
-
-
6
100
0,27
0,14
0,19
0,05
9
150
0,56
0,28
0,14
0,06
12
200
-
0,53
0,25
0,09
15
250
-
0,82
0,38
0,14
18
300
-
1,12
0,51
0,18
21
350
-
-
0,70
0,24
24
400
-
-
0,91
0,31
27
450
-
-
1,13
0,40
30
500
-
-
-
0,49
33
550
-
-
-
0,58
36
600
-
-
-
0,68
39
650
-
-
-
0,79
42
700
-
-
-
0,90
45
757
-
-
-
1,04
Recommendations:
1. Rain Bird recommends flow rates in the supply line not to exceed 7.5 ft/sec. (2,29 m/s) in order to reduce the effects of water hammer.
2. For flows below 5 gpm (1,14m3/h; 19,2 l/m), Rain Bird recommends use of upstream filtration to prevent debris from collecting below the diaphragm.
3. For flows below 10 gpm (2,27 m3/h; 37,8 l/m), Rain Bird recommends the flow control stem be turned down two full turns from the fully open position.