The LDI/SDI Two-Wire Decoder Interface serves as an interface between the Central Controller and Rain Bird field and sensor decoders on the SiteControl System.
| Model Number | Description |
| Large Decoder Interface (LDI) | |
| LDITURF | LDI North America - interface with up to 500 decoder addresses and can activate up to 1,000 solenoids, includes transformer |
| ILDITURF | LDI International - interface with up to 500 decoder addresses and can activate up to 1,000 solenoids, does not include a transformer |
| Small Decoder Interface (SDI) | |
| SDITURF | SDI North America - interface with up to 200 decoder addresses and can activate up to 400 solenoids, includes transformer |
| ISDITURF | SDI International - interface with up to 200 decoder addresses and can activate up to 400 solenoids, does not include transformers |
| Domestic (USA) Field Decoders, Sensor Decoders and Surge Protection | |
| FD-101TURF | Field Decoder interfacing signal line and individual valve |
| FD-102TURF | Field Decoder interfacing signal line and valve or one pair of valves |
| FD-202TURF | Field Decoder interfacing signal line and 2 valves or 2 pair of valves |
| FD-401TURF | Field Decoder interfacing signal line and up to 4 individual valves |
| FD-601TURF | Field Decoder interfacing signal line and up to 6 individual valves |
| LSP-1TURF | Line Surge Protection |
| MSP-1 | Ground Two-Wire Path at LDI/SDI - Maxi Surge Pipe |
| SD-210TURF | Sensor Decoder interfacing signal line and analog or digital decoders |
| International Field Decoders, Sensor Decoders and Surge Protection | |
| FD-101GOLF | Field Decoder interfacing signal line and individual valve |
| FD-102GOLF | Field Decoder interfacing signal line and valve or one pair of valves |
| FD-202GOLF | Field Decoder interfacing signal line and 2 valves or 2 pair of valves |
| FD-401GOLF | Field Decoder interfacing signal line and up to 4 individual valves |
| FD-601GOLF | Field Decoder interfacing signal line and up to 6 individual valves |
| LSP-1 | Line Surge Protection |
| MSP-1 | Ground Two-Wire Path at LDI/SDI - Maxi Surge Pipe |
| SD-210 | Sensor Decoder interfacing signal line and analog or digital decoders |
North America
- Input: 120 VAC ± 10% @ .75A 60Hz
- Output: 24VAC @ 3.12A 60Hz
International Recommended Specifications (Transformer not supplied)
- Input: 220, 230, 240VAC ± 10%, 50Hz
- Output: 24VAC @ 3.12A 50Hz
North America
- Input: 120 VAC ± 10% @ .59A 60Hz
- Output: 24VAC @ 2A 60Hz
International Recommended Specifications (Transformer not supplied)
- Input: 220, 230, 240VAC ± 10% @ 0.36A 50Hz
- Output: 24VAC @ 2A 50Hz